IEC

Equipment certification status - Official Certificate (2 Pages Letter)

International Standards IEC 61557 • ISO/IEC 17025 Metrological Traceability • Verification Status

Public Portal
Technical Drawing
Guangzhou ETCR Electronic Technology Co., Ltd.
China Electrical Instrumentation Verification Service (CEIVS)
Add: No.8 Yongxing He Xingdong Street, Taihe Town, Baiyun District, Guangzhou, China
Tel: +86-020-62199556      Fax: +86-020-62199550
Website: https://CEIVS-verification.pages.dev

REPORT OF PRODUCTS CALIBRATION VERIFICATION

✓ APPROVED & CERTIFIED COMPLIANT WITH STANDARDS REG-AUTHENTIC IEC 61557-5 / ISO 17025
Product Name:
Clamp Earth Resistance Tester
Model/Type:
ETCR 2100A+
Serial No.:
CERT-2024-8849
Applicable Standard:
IEC 61557-5:2019 / IEEE 81 / ISO/IEC 17025:2017
Calibration Purpose:
Grounding loop resistance & fault loop impedance verification
Conclusion:
PASS / APPROVED
Verified by (Stamp):
CERTIFICATION TEAM
Approved by LAN SEN YANG
Inspected by JIN HU PAN
Verified by WEI GAO LU
OFFICIAL STAMP
★ APPROVED ★
APPROVED • ADMITTED
CEIVS / CERTIFIED
Authorized Calibration Laboratory
CEIVS ONLINE VERIFICATION
China Electrical Instrumentation Verification Service

Scan QR code with any mobile device to verify certificate authenticity, metrological traceability and compliance with international standards (IEC 61557 / ISO/IEC 17025).

QR Code SCAN TO VERIFY
Verification Date: 27' July, 2026
Suggested Validity: 12 Months  |  Valid Until: 27' July, 2027
Technical Drawing
Technical Drawing
Calibration Report: Clamp Earth Resistance (Loop Impedance Method)
ISO/IEC 17025 TRACEABLE • IEC 61557-5
1.   Environmental conditions during verification:
(Temperature) 22±3 °C          (RH) 50~60 %          (Barometric Pressure) 101.3 kPa
2.   Reference normative documents:
• IEC 61557-5:2019: Equipment for testing, measuring or monitoring protective measures - Part 5: Resistance to earth.
• IEEE Std 81 / IEC 60364-6: Guide for Measuring Earth Resistivity, Ground Impedance, and Safety Verification.
• JJG1054-2009: Verification Regulation of Clamp Earth Resistance Meters.
3.   Measurement standards used in calibration (Metrological Traceability):
Standard device / Model specification Certificate / Pattern No. Traceability laboratory Accuracy class Valid until
Standard Grounding Calibration Loop / JDB-2 GIM-ER-88412 Guangdong Institute of Metrology (GIM) Grade 0.05 (U<0.20%) 2027/12/27
4.   Verification test items & safety inspection:
4.1 Jaw alignment & magnetic closure: PASS (P)
4.4 50Hz Industrial noise rejection (>40dB): PASS (P)
4.2 Jaw eccentric position effect: PASS (P)
4.5 Withstand voltage (Jaws to case 3700V): PASS (P)
4.3 Measurement repeatability (s < 0.5%): PASS (P)
4.6 AC Leakage Current test (1mA, 10mA, 1A): PASS (P)
Table 1: Earth Loop Resistance Calibration & Expanded Uncertainty (k=2, 95% Confidence)
Nominal Pattern (Ω) Instrument Reading (Ω) Absolute Error Expanded Uncertainty (U) Normative Limit (IEC 61557-5) Conclusion
0.50 Ω 0.51 Ω +0.01 Ω ± 0.008 Ω (k=2) Operating Error ≤ ±30% PASS
1.00 Ω 1.02 Ω +0.02 Ω ± 0.015 Ω (k=2) Operating Error ≤ ±30% PASS
5.00 Ω 4.98 Ω -0.02 Ω ± 0.035 Ω (k=2) Operating Error ≤ ±30% PASS
10.00 Ω 10.05 Ω +0.05 Ω ± 0.080 Ω (k=2) Operating Error ≤ ±30% PASS
20.00 Ω 19.92 Ω -0.08 Ω ± 0.120 Ω (k=2) Standard Threshold (≤20.0 Ω) PASS
50.00 Ω 50.30 Ω +0.30 Ω ± 0.350 Ω (k=2) Operating Error ≤ ±30% PASS
100.0 Ω 99.40 Ω -0.60 Ω ± 0.850 Ω (k=2) Operating Error ≤ ±30% PASS
*Note: Calibrated via induction loop standard with closed jaws. Operating uncertainty and error well within IEC 61557-5 limits. Max Relative Error: < ±0.70% (PASS)
5. Conclusion for the verification: PASS (合格) — Full Compliance with IEC 61557-5 & ISO/IEC 17025 Standards
CEIVS METROLOGY VERIFICATION SYSTEM • ACCREDITED TO ISO/IEC 17025
CERTIFICATION TEAM
Approved by LAN SEN YANG
Inspected by JIN HU PAN
Verified by WEI GAO LU
OFFICIAL STAMP
★ APPROVED ★
APPROVED • ADMITTED
CEIVS / CERTIFIED
Technical Drawing